Common GN30A Ready Heater Parts:
|
|
GN30A Reddy Heaters Blueflame ventfree Heaters for garages
|
|
|
|
|
-
Wall Mount Heater
-
GN30A - Natural Gas Reddy Heater
-
Manual Control Operation
-
Save on heating costs. The 99% heating efficient designs require no outside
venting, so all the heat stays in the room.
-
The GN30A Provides easy, economical installation, with no vent or chimney required,
and a built in pressure regulator, this heaters installation is an easy job*. (*Professional
installation recommended)
-
Safe and clean burning, Reddy Heaters ventfree garage heaters are design certified
by the American Gas Association and meet or exceed all government safety
performance standards.
-
A dual purpose safety pilot system protects against oxygen depletion and
any interruption in the fuel supply. If either occurs, the gas is shut
off to the burner, turning the heater off.
-
Provides heat during power outages. No electricity required, making them
ideal as back up emergency heat.
-
Clean, quiet, odorless operation
-
Reddy Heaters GN30A has easy to use top mounted controls
-
push button ignition. No matches required.
- Sheet metal panel & safety grill (this unit does not have glass)
-
Low heat 15,000 BTU's
-
High heat 30,000 BTU's
- GN30A Heater Dimensions 24.5" H x 25.5" W x 8" D
- More Reddy heaters
|
|
|
|
Important Heater Information |
|
|
|
|
- Heater Installation must be done by
qualified
service persons.
- Read Owner's Manual before using.
- Check
local codes and ordinances for permitted vent free heater uses.
- Not for use in recreational
vehicles.
- All heater products approved for
manufactured
(mobile) home installation.
- We reserve the right to amend
heater
specifications without
notice.
- Use with adequate air (ventilation)
only. vent free heaters humidify while
they heat.
- Vent free provides water vapor in the area
heated. Refer to owner's
manual for specifics.
- Heating areas based on rooms with
8'
ceilings.
- Operating heaters at elevations
above
4,500 ft. could cause
nuisance outages.
- Other propane/LP gas Reddy Heaters:
GN30TA |
- Operating GN30A heaters at elevations above 4,500 ft. could cause nuisance outages. REASON: thinner air at higher elevations causes the ODS pilot to shut the heater off. This is accomplished as the pilot flame lifts off of the thermocouple ceasing the signal sent to the gas valve.
- Vent free heater can not be converted between
fuel types.
- ANSI Z21 11.2 Standard and National
Fuel Gas Code revised
in 1994 to permit wall mounted installations of 10,000 btu vent free heaters in bedrooms and 6,000 Btu in Bathrooms.
Always
check local codes before installing |
|
|
|
|