Common GWRN18TA Glo-Warm Parts:
* If replacing ODS pilot and your model is Pre 2002, your part number
will be 100701-03 for natural gas models.
The thermocouple part number will be 098514-01 (See Fig 3). The electrode
part number will be 098594-01.
Click Here for Owners Manual
GWRN18TA Glo-Warm Natural gas heaters are vent free Infrared heaters,
with thermostat control and 18,000 btu’s
Glo-Warm
infrared heaters direct heat from radiant plaques that "warm
like the sun."
Infrared heaters heat objects in the room before the air,
making them ideal for un-insulated rooms in your home.
|
|
GWRN18TA Glo-Warm Plaque Infrared Heaters
|
|
|
|
|
- GWRN18TA - Natural Gas Heaters
- Wall mounted heater (optional floor kit sold seperately)
- Thermostat Control Operation
- Save on heating costs. The 99% heating efficient designs require no outside
venting, so all the heat stays in the room.
- The GWRN18TA heaters provide easy, economical installation, with no vent or chimney required,
and a built in pressure regulator, installation is an easy job*. (*Professional
installation recommended)
- Safe and clean burning, Glo-Warm vent free gas heaters are design certified
by the American Gas Association and meet or exceed all government safety performance
standards.
- A dual purpose safety pilot system protects against oxygen depletion and
any interruption in the fuel supply. If either occurs, the gas is shut off
to the burner, turning the heater off.
- Provides heat during power outages. No electricity required, making them
ideal as back up emergency heat.
- Clean, quiet, odorless operation
- Glo-Warm GWRN18TA heaters have easy to use top mounted controls
- Push button ignition. No matches required.
- Decorative safety grille
- Low heat 6,600 BTU's (Natural Gas model)
- *Thermostatic controlled heaters work by turning the heat on and off in order
to keep a constant temperature.
- High heat 18,000 BTU's (Natural Gas model)
- GWRN18TA Heater Dimensions 24.5" H x 18.25" W x 8" D
|
|
|
|
|
Important Heater Information |
|
|
|
|
- Heater Installation must be done by
qualified
service persons.
- Read Owner's Manual before using.
- Check
local codes and ordinances for permitted ventfree heater uses.
- Not for use in recreational
vehicles.
- All heater products approved for
manufactured
(mobile) home installation.
- We reserve the right to amend
heater
specifications without
notice.
- Use with adequate air (ventilation)
only. ventfree heaters humidify while
they heat.
- Ventfree provides water vapor in the area
heated. Refer to owner's
manual for specifics.
- Heating areas based on rooms with
8'
ceilings.
- Other natural gas Glo Warm Heaters:
GWRN10 GWRN18A GWRN30A GWRN30TA |
- Operating GWRN18TA heaters at elevations
above 4,500 ft. could cause nuisance outages.
REASON: thinner air at higher elevations causes the 110803-03 and 100701-03 ODS pilot to shut the heater off. This is accomplished as the pilot flame lifts off of the 110186-01 and 098514-01 thermocouple ceasing the signal sent to the gas valve.
- Ventfree heater cannot be converted between
fuel types.
- ANSI Z21 11.2 Standard and National
Fuel Gas Code revised
in 1994 to permit wall mounted installations of 10,000 btu ventfree heaters ( GWRN10 in bedrooms.
Always
check local codes before installing
|
|
|
|
|