|
Common GWRP10 Glo Warm Parts:
Click Here for Owners Manual
GloWarm Propane heaters GWRP10 is a ventfree Infrared heater,
with manual control and 10,000 btu’s
GloWarm
infrared heaters direct heat from radiant plaques that "warm
like the sun."
Infrared heaters heat objects in the room before the air,
making them ideal for un-insulated rooms in your home.
|
|
GWRP10 GloWarm Plaque Infrared Heaters GWRP10
|
|
|
|
|
-
GWRP10 - Propane Heater (LP)
- Wall mounted heater
- Manual Control Operation
-
Save on heating costs. The 99% heating efficient designs require no outside
venting, so all the heat stays in the room.
-
The GWRP10 heater provides easy, economical installation, with no vent or chimney required,
and a built in pressure regulator, installation is an easy job*. (*Professional
installation recommended)
-
Safe and clean burning, GloWarm ventfree gas heaters are design certified
by the American Gas Association and meet or exceed all government safety
performance standards.
-
A dual purpose safety pilot system protects against oxygen depletion and
any interruption in the fuel supply. If either occurs, the gas is shut
off to the burner, turning the heater off.
-
Provides heat during power outages. No electricity required, making them
ideal as back up emergency heat.
-
Clean, quiet, odorless operation
-
GloWarm GWRP10 heaters have easy to use top mounted controls
- Push button ignition. No matches required.
-
Decorative safety grill
-
Low heat 5,000 BTU's
-
High heat 10,000 BTU's
- GWRP10 Heater Dimensions 21.5" H x 13.5" W x 7" D
|
|
|
|
|
Important Heater Information |
|
|
|
|
- Heater Installation must be done by
qualified
service persons.
- Read Owner's Manual before using.
- Check
local codes and ordinances for permitted ventfree heater uses.
- Not for use in recreational
vehicles.
- All heater products approved for
manufactured
(mobile) home installation.
- We reserve the right to amend
heater
specifications without
notice.
- Use with adequate air (ventilation)
only. ventfree heaters humidify while
they heat.
- Ventfree provides water vapor in the area
heated. Refer to owner's
manual for specifics.
- Heating areas based on rooms with
8'
ceilings.
- Other propane / LP Glo Warm Heaters:
GWRP16A GWRP16TA GWRP26A GWRP26TA |
- Operating GWRP10 heaters at elevations
above 4,500 ft. could cause nuisance outages.
REASON: thinner air at higher elevations causes the 099059-03 pilot to shut the heater off. This is accomplished as the pilot flame lifts off of the 098514-01 thermocouple ceasing the signal sent to the gas valve.
- Ventfree heater cannot be converted between
fuel types.
- ANSI Z21 11.2 Standard and National
Fuel Gas Code revised
in 1994 to permit wall mounted installations of 10,000 btu ventfree heaters GWRP10 GWRN10 in bedrooms.
Always
check local codes before installing |
|
|
|
|