Common GWN6 GloWarm Parts:

* If replacing ODS pilot and your model is Pre 2002, your part number
will be 100701-03 for natural gas models.
The thermocouple part number will be 098514-01 (See Fig 3) for both gases. The electrode
part number will be 098594-01 for both gases.

110186-01 098514-01 120790-01 thermocouple for ODS pilot GWN6 glowarm heater parts

Click Here for Owners Manual


GWN6 GloWarm Natural gas heater is a ventfree BlueFlame heater,
with manual control and 6,000 btu’s

The GWN6 BlueFlame heater works much like a central heating system,
the room is wrapped in a blanket of comfort as the air is warmed.

A GloWarm BlueFlame heater does not require electricity to run,
enabling you to weather the cold with power or without.




GloWarm Blueflame Heater GWN6





  • GWN6 - Natural Gas heaters
  • Manual Control Operation
  • Wall Mount heater
  • Save on heating costs. The 99% heating efficient designs require no outside venting, so all the heat stays in the room.
  • Blueflame ventfree heaters provide easy, economical installation, with no vent or chimney required, and a built in 099415-17 pressure regulator, installation is an easy job*.
  • *Professional installation recommended
  • Safe and clean burning, GloWarm ventfree heaters are design certified by the American Gas Association and meet or exceed all government safety performance standards.
  • A dual purpose safety ODS pilot system 110803-01 or 100701-03 protects against oxygen depletion, when the pilot flame is lifted from the 110186-01 or 098514-01 thermocouple the gas is shut off to the burner by the 110803-01 or 100701-03 ODS pilot causing the heater to turn off.
  • Provides heat during power outages. No electricity required, making these ventfree heaters ideal as back up emergency heat.
  • Clean, quiet, odorless operation
  • Easy to use  top mounted controls
  • 097159-04 piezo igniter push button ignition. No matches required.
  • Decorative safety grill and tinted glass
  • Low heat 4,400 BTU's
  • High heat 6,000 BTU's
  • Heater Dimensions 21.5" H x 13.5" W x 7" D




Important Heater Information



  • Heater Installation must be done by qualified service persons.
  • Read Owner's Manual before using.
  • Check local codes and ordinances for permitted ventfree heater uses.
  • Not for use in recreational vehicles.
  • All heater products approved for manufactured (mobile) home installation.
  • We reserve the right to amend heater specifications without notice.
  • Use with adequate air (ventilation) only. ventfree heaters humidify while they heat.
  • Ventfree provides water vapor in the area heated. Refer to owner's manual for specifics.
  • Heating areas based on rooms with 8' ceilings.
  • Other natural gas Glo Warm Heaters:
    GWN10 GWN10T GWN20TA GWN30TA
  • Operating GWN6 heaters at elevations above 4,500 ft. could cause nuisance outages.
    REASON: thinner air at higher elevations causes the 110803-01 and 100701-03 ODS pilot to shut the heater off. This is accomplished as the pilot flame lifts off of the 110186-01 and 098514-01 thermocouple ceasing the signal sent to the gas valve.
  • Ventfree heater cannot be converted between fuel types.
  • ANSI Z21 11.2 Standard and National Fuel Gas Code revised in 1994 to permit wall mounted installations of 10,000 btu ventfree heaters ( GWN10T GWN10 GWP10T GWP10 ) in bedrooms and 6,000 btu heaters ( GWN6 GWP6 ) in bathrooms.